PHARMACEUTICAL INDUSTRY LUBRICANTS

Tablet presses, granulators, blister packing lines and clean-room utilities need lubricants that protect the machine without putting product quality or audits at risk.

In a pharmaceutical plant a lubricant is judged on two counts: does it protect the machine, and could it ever reach the product? Tablet press punches and cams, capsule fillers, blister packers and cartoners have lubrication points close to open product or primary packs. Auditors expect a documented choice of lubricant for every point, with H1-registered products wherever incidental contact is possible. Near product zones the safe default is an NSF H1 registered lubricant, applied sparingly and recorded.

Banesto supplies NSF H1 registered white grease, PTFE dry-film lubricant for clean areas, long-life bearing grease for motors and air-handling fans, and oils and belts for gearboxes, compressors and utilities.

Lubrication Challenges in Pharmaceuticals

Incidental Product Contact
Punches, cams and packing machine parts work close to open product; H1 lubricants reduce the contamination risk.
Audits & Documentation
GMP audits look for a lubricant list, H1 certificates and records of where each lubricant is used.
Clean-Room Conditions
Oily residues attract dust and are hard to clean; dry films and controlled greasing help.
Frequent Cleaning
Regular cleaning with water and sanitisers removes ordinary lubricants from exposed points.

Recommended Banesto Products

Selected from our 852+ SKU range for the duty cycles most common in pharmaceutical plants. Every recommendation is matched by application (temperature, load, speed and exposure), not by catalogue number. Where the equipment maker specifies a grade, the maker's specification comes first.

Food-Grade White Grease (NSF H1)
NSF H1 · NLGI 2 · WHITE
Odourless, tasteless grease for tablet press, capsule filler and packing machine points with incidental contact risk.
View Product →
PTFE Dry-Film Lubricant
PTFE · 260 °C · LOW FRICTION
Dry, clean lubrication for guides, slides and plastic parts where an oily film is unacceptable.
View Product →
Polyurea Long-Life Bearing Grease
NLGI 2 · POLYUREA · LOW NOISE
For motors, AHU fans and pumps in utilities: quiet, long-life and stable at speed.
View Product →
Industrial Gear Oil (ISO 220)
ISO VG 220 · EP
For blender, mixer and conveyor gearboxes located outside product zones.
View Product →
Compressor Oil (ISO 100)
ISO VG 100
For lubricated reciprocating compressors in utilities, where VG 100 is specified.
View Product →
Beltone Wedge Belt
SPZ · SPA · SPB · SPC
For AHU and cooling-tower fan drives; oil and heat resistant, static conductive.
View Product →

Need specifications? Full technical data sheets are available for every grade.

View Product Datasheets →

Lubrication Map: Machine by Machine

A starting point for your lubrication schedule, point by point.

EquipmentLubrication pointBanesto productGood practice
Tablet pressesPunches, guides, cams (incidental contact zone)Food-Grade White Grease NSF H1Apply sparingly and wipe off excess before production.
Capsule fillers, blister and cartoning machinesCams, chains, guidesNSF H1 grease or PTFE Dry-FilmRecord every point in the lubrication register.
Blenders, granulators, coating pansDrive gearboxes outside the product zoneIndustrial Gear Oil ISO VG 220, or the maker's gradeCheck seals so oil can never weep towards product.
AHUs, pumps, motorsBearingsPolyurea Long-Life Bearing GreaseFollow the motor plate for quantity and interval.
AHU and cooling-tower fansBelt drivesBeltone wedge belts (SPZ, SPA)Check tension at every preventive-maintenance visit.
Utility compressorsCrankcaseCompressor Oil ISO VG 100 for lubricated compressorsUse oil-free compressors or proper filtration for product-contact air.

Frequently Asked Questions

What does NSF H1 mean?

NSF H1 is the registration for lubricants acceptable where incidental contact with food may occur; pharmaceutical plants apply the same standard near product. H1 lubricants are formulated with ingredients permitted under FDA 21 CFR 178.3570.

Do pharmaceutical plants need H1 lubricants everywhere?

Not everywhere. H1 is the safe choice wherever incidental contact is possible: near open product, primary packs and product-contact parts. Utilities and enclosed equipment away from the product can use standard industrial lubricants, as set by your plant's risk assessment.

Can H1 grease be mixed with the old grease?

Avoid it. Purge the old grease completely when converting a point to H1; otherwise the mixture is no longer H1 and the thickeners may not be compatible. See can you mix two greases.

What do auditors usually ask for?

A lubricant list by machine and point, H1 registration evidence, data sheets and safety data sheets, and records of lubrication done. Ask us for the data sheets of the grades you use.

Preparing for a GMP audit or converting a line to H1? Send us your machine list and our team will mark every lubrication point and prescribe the right grade for each.